032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia

Brand Name : Brando

Model Number : EVRA 25

Certification : CE

Place of Origin : China

MOQ : 1 set

Payment Terms : L/C, T/T, Western Union,Paypal, MoneyGram

Supply Ability : 5000 sets per month

Delivery Time : 4-8 days

Packaging Details : Inner Box, Carton, Pallet

Ref number : 032F6225(Without Coil), 032F803432(With Coil)

Connection size : 1'' Inch, DN25

Connection type : Steel Flange Set

Operation : Servo piston operated

Function : 2-way NC (Normally Closed)

Ambient temperature : -40 to 80 °C

Body material : Cast iron

Voltages : 110VAC, 220VAC, 230VAC, 12VDC, 24VDC

Refrigerants : R134a R22 R401A R402A R404A R407A R407B R407C R407F R409A R410A R421A R502 R507 R717

Max. Working Pressure : 42 Bar

Contact Now

032F6225 032F803432 EVRA 25 s Type Servo-Piston Operated Flange Solenoid Valve For Ammonia

Product overview of 032F6225 032F803432 EVRA 25 s Type Servo-Piston Operated Flange Solenoid Valve For Ammonia:

The EVRA 25 s 032F6225 ammonia solenoid valve is used for automated opening and closing in ammonia network in both liquid and

gaseous phases. The EVRA valve is sold dismembered with body + flange set + coil supplied. In addition to this convenience, repairs are sold

separately. Thus, the valve can be repaired in the pipeline without removal, giving more agility and reliability to the process.

Main dimension of EVRA 25 s Type Flange Ammonia Solenoid Valve:

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia 032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia

Technical parameters of EVRA 25 s Type Flange Solenoid Valve For Ammonia:

Type Opening differential pressure with standard coil ( ∆p bar) Temperature of medium (°C) Max. working pressure (bar) kv-value (m³/h)
Min. Max. (= MOPD) liquid²)
10W AC 12W AC 20W DC
EVRA 3 0.00 21 25 14 -40 to 105 42 0.23
EVRA 10 0.05 21 25 18 -40 to 105 42 1.5
EVRAT10 0.00 14 21 16 -40 to 105 42 1.5
EVRA 15 0.05 21 25 18 -40 to 105 42 2.7
EVRAT15 0.00 14 21 16 -40 to 105 42 2.7
EVRA 20 AC 0.05 21 25 13 -40 to 105 42 4.5
EVRA 20 DC 0.05 19 21 16 -40 to 105 42 4.5
EVRAT20 0.00 14 21 13 -40 to 105 42 4.5
EVRA 25 0.20 21 25 14 -40 to 105 42 10.0
EVRA 32 0.20 21 25 14 -40 to 105 42 16.0
EVRA 40 0.20 21 25 14 -40 to 105 42 25.0

Details of 032F6225 032F803432 EVRA 25 s Type Refrigeration Solenoid Valve:

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia

Packing display of 032F6225 032F803432 EVRA 25 S Type Flange Valve:

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia

Video display of 032F6225 032F803432 EVRA 25 s Type Ammonia Valve:

Instructions to the Welder
1. Always use TIG / Argon welding as the root run, to avoid slag and debris entering the valve house.
2. Complete the welding process according to local legal requirements.
3. Inspect the inside around the welding and remove all debris.

Instructions to the Installer
1. Clean the pipes and valve houses with dry air (no water, no sandblasting).
2. Lubricate valve housing sealing surfaces (e.g. with refrigerant oil).
3. Follow the valve installation instructions.
4. Pressure test the system with dry air or inert gas (no water).

Instructions to the Supervisor
1. Build up the system in sections. For example, have valve trains or valve stations pre-manufactured before being shipped on site, or make it in a separate clean workshop on site, where welding and cleaning procedures can be easily controlled.
2. Evacuate the sections to verify that there is no water left in the system.
3. Seal and pressurize finished sections slightly with inert gas.
4. Evacuate down to 5-10 mbar before charging refrigerant.
5. Run free and clean filters frequently for 24-48 hours.

Focus on your demands, Offer you best solution:

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

Welcome to your any question and inquiry!


Product Tags:

normally closed solenoid valve

      

liquid line solenoid valve

      
Quality 032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia for sale

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)